NYQ-THC-51 High Professional Gas Chromatography
Features: |
|
1. Use EPC technic to control carrier gas pressure, stable accuracy, accuracy better than ±0.05Kpa |
|
2. Use EFC technic to control flow of hydrogen & air, accuracy better than 0.5% F.S |
|
3. Choose FID or PID sensor as requests, flexible & portable configuration |
|
4. Controllable accuracy of oven better than ±0.1℃ |
|
5. Use diaphragm pump with low maintenance & constant volume sampling by sample loop |
|
6. Use imported 10-valve / 6-valve, low maintenance, long service life |
|
7. Use Double column parallel back flushing technic to analyze non-methane hydrocarbon, reduce peak stretch, shorten analysis time |
|
8. Built-in standard industrial PC, high-definition, colour LCD touch screen, excellent human-interaction controllable software interface, all system run automatically based on microsoft window opertion system |
|
9. 25 inch standard case, compact structure, install into vertical cabinet with same type instruments, small occupying area, easy daily maintenance & operation |
|
Application: |
|
Online monitor the organized & organic waste gas emission of petrochemical, chemical, printing, spraying and coating, etc. |
|
Organic waste gas recovery |
|
Online monitor the result before / after treatment |
|
Monitor benzene series of ambient air for petrochemical & chemical park |
|
Monitor benzene series of ambient air for occupational health |
|
Working Principle: |
|
Use FID or PID to analyze the organic gas |
|
Techinical Parameter: |
|
FID |
|
Measuring Range: |
0.1~100/1~1000/10~10000ppm (or as request) |
Sensor: |
Highly sensitive FID sensor |
LOD: |
Methane: 0.1ppm |
NMHC: 0.05ppm |
|
Analytical Cycle: |
<1.5min (Methane, NMHC) others depend on factor |
Reproducibility: |
<3% |
Gas Consumption: |
|
Zero air: |
200ml/min |
H2: 20ml/min |
|
Sampling Method: |
Draw-out type with whole processing high heat tracing |
Analysis Method: |
Gas chromatography |
Work Temperature: |
5~35℃ |
Signal Output: |
RS232, 4-20mA |
Size: |
25 inch |
Function: |
LCD Display, Auto-alarm, Auto-measuring |
PID |
|
Measuring Range: |
0~300ppb (or as request) |
Material: |
Benzene, Methylbenzene, Ethylbenzene, M-xylene, P-xylene and O-xylene |
LOD: |
<0.1ppb (benzene) |
Reproducibility: |
RSD≤3% (benzene) |
Analytical Cycle: |
≤15min |
Sensor: |
Photoionization PID sensor |
Sample volume: |
5~300ml (standard status, adjustable) |
Thermal Desorption: |
300℃ max |
Desorption speed: |
40℃/s max |
Carrier Gas of gas source: |
Highly purified nitrogen (>99.995%) |
Signal Output: |
4~20mA, RS232/RS485, Ethernet |
Size: |
19 inch standard case |
|