1. Overview
The TR-9300D flue gas continuous monitoring system is a combination of the world's advanced online analytical technology and China's environmental monitoring technology, and has been carefully crafted through our company's many years of experience in the industrial process field. The system complies with the environmental protection industry standard HJ/T76-2007 of the People's Republic of China and has obtained the “Environmental Protection Product Certification Certificate” issued by China Environmental Protection Industry Association. The system is applied to the on-line monitoring of gaseous pollutants (SO2, NOx, CO, CO2, O2) and solid pollutant dust in the flue gas as well as temperature, pressure, humidity and flow, and generates maps and environmental reports through the data acquisition and processing system. Data can be passed to all levels of environmental protection.
2. Composition
Gaseous pollutant monitoring subsystem (SO2, NO, O2, CO, CO2, etc.)
Particle monitoring subsystem (dust)
Flue gas parameter monitoring subsystem (flue gas temperature, pressure, flow rate, humidity)
Data Processing Subsystem (DAS System)
The data transmission system is composed.
3. System features
Small system maintenance
System modular structure design, flexible configuration
Strong anti-interference performance
Easy system operation and easy maintenance
High system measurement accuracy
High system data acquisition accuracy
Long system life
4. Application field
The system is applied to various power plants, chemical plants, steel plants, heating plants, cement plants, waste incineration plants, and various types of fuel oil, coal, gas boilers.
5. Technical parameters
Measurement method |
Measurement range |
Zero drift |
Range drift |
Response time |
Linear error |
Output signal |
|
0~100~2000PPm |
±1%FS/7d |
±1%FS/7d |
≤12 |
≤±1%FS |
RS-232/485 |
||
Infrared or ultraviolet |
0~100~2000PPm |
±1%FS/7d |
±1%FS/7d |
≤12 |
RS-232/485 |
||
0~100~2000PPm |
±1%FS/7d |
±1%FS/7d |
≤12 |
RS-232/485 |
|||
O2 |
Electrochemical or Magnetic pressure type |
0~25% |
±1%FS/7d |
±1%FS/7d |
≤10 |
RS-232/485 |
|
Optical method or laser |
0~100~2000mg/m3 |
±2%FS/7d |
±2%FS/7d |
≤1 |
≤±3%FS |
4~20mA |
|
Flow rate |
Differential pressure sensing |
0~40m/S |
±5%FS/7d |
±5%FS/7d |
≤15 |
≤±1%FS |
4~20mA |
pressure |
Differential pressure sensing |
-40~40KPa |
±2%FS/7d |
±2%FS/7d |
≤±1%FS |
4~20mA |
|
temperature |
Thermocouple |
0~250℃ |
±1%FS/7d |
±1%FS/7d |
≤±1%FS |
4~20mA |
|
humidity |
Capacitance method |
0~100% |
±2%FS/7d |
±2%FS/7d |
≤10 |
≤±1.5%FS |
4~20mA |