1, 3.5 "TFT true color LCD screen color display, simple operation, clearer interface display
2. 16G memory, large data storage and easy export
3. The instrument can automatically calculate the results, and the data can be exported through automatic USB, no computer software is required.
4. The instrument can directly communicate with the computer through the USB cable to export the measured data and calculation results. The data is saved in Excel format, and various data are displayed separately, and various charts and curves can be generated.
5. The instrument uses a miniature gas flow meter, and the flow rate can be set by the instrument
Technical Index of FS-3080A Fruit and Vegetable Respirator
Carbon dioxide detection
Detection principle: infrared
1. Minimum measurement range: 0-5000ppm
2. Resolution: 1ppm
3. Linearity: ≤ ± 1% F.S
4. Repeatability: ≤ ± 1%
5. Response time: ≤15s
6. Zero drift: ≤ ± 2% F.S / 24h
7. End point drift: ≤ ± 2% F.S / 24h
Oxygen test
Detection principle: electrochemical
1. Measuring range: 0-100%
2. Linearity: ≤ ± 2% F.S
3. Repeatability: ≤ ± 1%
4. Response time: 30s
5. Zero point drift: ≤ ± 2% F.S / 24h
6. End point drift: ≤ ± 2% F.S / 24h
temperature check
Measurement range: -20-95 ° C Resolution: 0.1 ° C Accuracy: ± 0.2 ° C
Humidity detection
Measuring range: 0-100% Resolution: 0.1% Accuracy: ± 0.2% F.S
Power source: AC220V ± 10%
2. 16G memory, large data storage and easy export
3. The instrument can automatically calculate the results, and the data can be exported through automatic USB, no computer software is required.
4. The instrument can directly communicate with the computer through the USB cable to export the measured data and calculation results. The data is saved in Excel format, and various data are displayed separately, and various charts and curves can be generated.
5. The instrument uses a miniature gas flow meter, and the flow rate can be set by the instrument
Technical Index of FS-3080A Fruit and Vegetable Respirator
Carbon dioxide detection
Detection principle: infrared
1. Minimum measurement range: 0-5000ppm
2. Resolution: 1ppm
3. Linearity: ≤ ± 1% F.S
4. Repeatability: ≤ ± 1%
5. Response time: ≤15s
6. Zero drift: ≤ ± 2% F.S / 24h
7. End point drift: ≤ ± 2% F.S / 24h
Oxygen test
Detection principle: electrochemical
1. Measuring range: 0-100%
2. Linearity: ≤ ± 2% F.S
3. Repeatability: ≤ ± 1%
4. Response time: 30s
5. Zero point drift: ≤ ± 2% F.S / 24h
6. End point drift: ≤ ± 2% F.S / 24h
temperature check
Measurement range: -20-95 ° C Resolution: 0.1 ° C Accuracy: ± 0.2 ° C
Humidity detection
Measuring range: 0-100% Resolution: 0.1% Accuracy: ± 0.2% F.S
Power source: AC220V ± 10%